DMS 5.0 Data measuring and moemory unit including software.
As per DIN/EN 1610.
For electronic inspection data logging and analysis of leakage tests in accordance with EN 1610 or ATV Form 143, Part 6, in air or water as well as for pressure pipes and vacuum chamber examination and tests.
The DMS 5.0 fully complies with EN 1610 requirements for accuracy, from 10% of allowable pressure drop. This provides the analogue-digital conversion, with an end resolution of 12Bit.
The maximum error in respect of the absolute error of measurement corresponds to + / - 1LSB, or + / - 0.06 mbar (250 mbar pressure sensor). The display corresponds to the value recorded in the controller to one exact decimal place (+ / - 1mbar). The measurement is updated every 2 seconds regardless of the selected sampling rate.
Hardware requirements
User hardware requirements:
- PC: IBM AT, PS/2 or similar
- min. 4MB RAM
- VGA-graphic card
- 1 free serial port
- Windows 3.1x or Windows 95 / 98
The installer program on the disc that the user receives when purchasing the software, determines the necessary hardware settings and creates the required directory and program icon.
Controller
Technical specifications:
- Aluminium – cast housing; dimension: 90 x 60 x 75 mm (L x B x H)
- Weight: 0,5 kg (incl. battery)
- Sensor: 1 pressure sensor 0 bis 250mbar, internal temperature sensor
- Analogue-digital-transformer, resolution 12Bit
- Real time clock, deviation +/- 5ppm at 25°C
- Operating temperature 0 bis 50°C
- Power supply 9V DC internal, Lithium Mangandioxide E Block
- Memory: 61kB
- Sample rate adjustable between 1s and 18h
Note
For more details, please refer to the manual or call to get free advice from the Supplier.